FIND THE PRODUCT YOU NEED!
The Best Tektronix TDS380
Tektronix TDS380
Bandwidth: 400 Mhz Channels: 2
400MHz Digital Oscilloscope
Capture real-time signals on each and every sweep with the new TDS380 Oscilloscope with twice the bandwidth and twice the sample rate of previous TDS300 models.
All models come with Fast Fourier Transform (FFT) to display harmonic content of waveforms. In addition, the TDS380 comes with a built-in floppy disk drive for simplified PC compatability.
These digital scopes will meet your needs in all areas: education, product design, manufacturing, service and troubleshooting.
Key applications include troubleshooting and verification of electronic circuitry, electronic products testing, installation, repair and performance of electronics products.
Single-shot capture to full bandwidth Enhanced measurement efficiency Efficient analysis of harmonics with FFT mode High-speed sampling that minimizes aliasing Desktop publishing of test reports Import waveform values into spreadsheet for analysis Bandwidth: 400 MHz Channels: 2 Max Sample Rate: 2 GS/s/channel Sweep Speeds: 2.5 ns/div – 5 s/div Vertical Sensitivity: 2 mV – 10 V Vertical Resolution: 8 Bits Record Length: 1 K/channel Standard Advanced Features FFT, TV Line & Field Trigger, Roll Mode, Autoset, 21 Automatic Measurements, Peak Detect, Floppy Disk Drive
IN STOCK
Description
Tektronix TDS380
Characteristics
Signal Acquisition System.
Bandwidth –
TDS 340A: 100 MHz.
TDS 360: 200 MHz.
TDS 380: 400 MHz.
Sample Rate –
TDS 340A: 500 MS/s on each channel.
TDS 360: 1 GS/s on each channel.
TDS 380: 2 GS/s on each channel.
Channels – Two identical channels, each with invert function.
Sensitivity – 2 mV to 10 V/div (with calibrated fine adjust).
Position Range – ±5 divisions. Time Base System (Main and Delayed)
Time/Division Range –
TDS 340A: 5 ns to 5 s/div.
TDS 360: 2.5 ns to 5 s/div.
TDS 380: 1 ns to 5 s/div.
Record Length – 1000 sample points per channel.
Horizontal Accuracy – ± 0.01%.
Roll Mode – 0.1 s/div and slower when Auto Trigger Mode is
selected.
Triggering System (Main Only)
Trigger Types – Edge, Video.
Trigger Modes – Auto, Normal.
Trigger Inputs – CH1, CH2, Line, External.
Video -Type Trigger Formats and Field Rates – Triggers on Field 1, Field 2, Any Field (noninterlaced systems), or Lines; from Sync-negative composite video.
Triggers on broadcast standard NTSC, PAL, or SECAM video and other interlaced and noninterlaced video with horizontal line rates from 15 to 65 kHz (in 5 ranges) and field rates from 50 to 60 Hz.
Display Sin(x)/x Interpolation.
Vector – Connects sample points to display a continuous
waveform.
Dots – Displays sample points only.
Vector Accumulate Mode – Accumulates waveform points over a pre-set period of time (500 ms to infinity) andsuperimposes the current waveform with bright vectors.
Dot Accumulate Mode – Accumulates waveform points over a pre-set period of time (500 ms to infinity).
Format – YT and XY.