FIND THE PRODUCT YOU NEED!

The Best Micronetics Power Meter

Micronetics Power Meter

Download

Micronetics Power Meter

A lightweight and portable lab grade power meter with a built-in frequency counter. This instrument is ideal for field-testing or laboratory use. Perform 100kHz to 2.6GHz CW power measurements over an 80dB dynamic range while the calibrator automatically performs background calibration. The meter also includes a frequency counter and the ability to download data to a PC via RS232 interface.

Description

Micronetics Power Meter

Perform 100 kHz to 2.6 GHz CW power
measurements over an 80 dB dynamic
range while a built-in calibrator automatically performs background calibration. Overview:
Micronetics’ Hand-Held Power
Meter combines a power
meter and frequency counter
with lab grade accuracy in a
portable package.
Perform 100 kHz to 2.6 GHz
CW power measurements
over an 80 dB dynamic
range while a built-in calibrator automatically performs background calibration. And the meter also
includes a 100 kHz to 2.6
GHz frequency counter. Specifications:
POWER METER
Frequency Range 100 kHz to 2.6 GHz
Power Range -60 to +20 dBm
Display Resolution
Selectable log mode 1, 0.1, 0.01, 0.001 dB
Selectable lin mode 2, 3, 4, or 5 significant digits
ACCURACY
System linearity ±0.04 dB over a 70 dB range
Calibration factor uncertainty ±3.5% for all frequencies
Sensor Module VSWR <1.2:1
Zero Set (digital set zero) 50 pw
Noise <200 pw
Zero drift <±200 pW during 20 minutes
Temp. coefficient of linearity 0.3%/°C
Calibrator frequency 100 kHz, nominal
Calibrator 0.0 dBm uncertainty 1.2%
Sensor (RF module)
Calibration automatic, background
RF module customer replaceable
Damage leve +23 dBm
FREQUENCY COUNTER
Frequency Range 100 kHz to 2.6 GHz (3 auto ranges)
100 kHz to 70 MHz, low range, typical
50 MHz to 560 MHz, mid range, typical
450 MHz to 2.6 GHz, high range, typical
Display Resolution 1 Hz, low; 10 Hz, mid; 100 Hz, high; 1 sec gate
Measurement Res. 1 Hz, low; 8 Hz, mid; 32 Hz, high; 1 sec
gateInput Range 0 dBm, (-5 dBm typical) to
+20 dBm
Damage Level +23 dBm
Timebase Stability
Standard
Temperature: ±2.5 ppm, 0 to 55°C
Aging: ±1 ppm per year
High Stability Option
Temperature: ±1.0 ppm, 0 to 55°C
Aging: ±1 ppm per year
Accuracy ±1 LSB ± timebase frequency
GENERAL SPECIFICATIONS
Approvals CE mark
Temperature range
Operating: 0 to 55°C (+32 to 131°F)
Storage: -40 to 70°C (-40 to 158°F) (excluding batteries)
Remote Interface RS 232
Battery life 8 hours, typical, power mode
8 hours, typical, low frequency
4 hours, typical, mid frequency
3-1/2 hours, typical, high frequency

Micronetics Power Meter

Conceptos Electronics 

Fiber Optic Parts

 

banner-telecomunicaciones

Request a quote

×

Hello!

Click one of our representatives below to chat on WhatsApp or send us an email to [email protected]

×