FIND THE PRODUCT YOU NEED!

The best DCW 150-12FT-P6611

DCW 150-12FT-P6611

This rugged, industrial quality DC/DC converter uses field proven topology to generate 150W output power.  It is a mature design with a track record in hundreds of applications.  This chassis-mount design is also optimized for cost efficiency

 

Description

DCW 150-12FT-P6611

This rugged, industrial quality DC/DC converter uses field proven topology to generate 150W output power.  It is a mature design with a track record in hundreds of applications.  This chassis-mount design is also optimized for cost efficiency.  Cooling is via baseplate to a heat-sinking surface and by natural convection.  Additional ruggedizing and conformal coating are available for applications that require higher immunity to shock, vibration and humidity. Low component count, large design headrooms, and the use of components with established reliability result in a high MTBF.  The DCW 150 is manufactured at our plant under strict quality control.

SPECIFICATIONS

Input Voltage Two standard input ranges are available:  20 – 60Vdc or 65 – 160Vdc  Consult factory for other  input voltages and ranges

Input Protection Inrush current limiting Varistor Reverse polarity protection Internal safety fuse Lower voltage than the specified minimum input will not damage the unit.

Isolation 1500VDC input to chassis,  1500VDC input to output,  500VDC output to chassis

Standards Designed to meet EN 60950  and related standards

EMI  EN55022 Class A with margins

Switching Frequency 55kHz +/- 3kHz

Output Voltage 12V, 24V, 48V or 125Vdc Consult factory for other voltages

Redundancy diode Not installed Available as option

Line/Load Regulation +/-1% combined

Dynamic Response Max 5% voltage deviation for 10% to 50% load step, with better than 1msec recovery time

Output Ripple/Noise Better than 1% of output voltage peak to peak or 0.2% RMS of the output voltage (20MHz BW)

Overload Protection Current limiting with short circuit protection (hiccup type)  Thermal shut-down with automatic recovery in case of insufficient cooling.

Output Overvoltage Protection Double regulator loop
Efficiency  Output voltage dependent Typically 80% at full load
Operating Temperature 0°C to 50°C for full specification Wider temperature ranges  available
Temperature Drift 0.03% per oC over operating temperature range
Cooling Conduction to customer heatsink or chassis and natural convection
Environmental Protection Basic ruggedizing Optional heavy ruggedizing and conformal coating is available
Shock/Vibration  IEC 61373 Cat 1 A&B
Humidity 5 – 95% non-condensing
MTBF 140,000 hours @ 45oC  Demonstrated MTBF is significantly higher
Indicators Green “Power ON” LED, visible through the cooling slots.

DCW 150-12FT-P6611